Thursday, March 2, 2023

1-D vs 3-D Transport Analysis of Contaminant Plume Extent

 A 1-D analysis of contaminant transport often greatly overestimates plume extent, resulting in an overly-conservative assessment.


A common question related to contaminant plumes: “How far downgradient will the plume extend?”

We may want to know this for several reasons:

       Will the plume reach a receptor at some distance from the source?

       How far should I place monitoring wells to measure the plume?

       And in some states (e.g. NJ) how far should I draw the boundary of the groundwater Classification Exception Area (CEA).


Possible Methods

To analyze plume extent from the source over time, we can perform screening analyses using models ranging from simple analytic 1-D solutions, to 3-D analytic and semi-analytic solutions. We could also use more costly and sophisticated 3-D numerical fate and transport models - - but to examine the difference between a 1-D model and a 3-D model, analytical solutions are perfectly capable analysis tools.


1-D Plume Transport Modeling

For many decades, from the 1970s through present, investigators and regulators have often explored the movement of a dissolved chemical plume extending downgradient from a steadily-releasing source using some form of mathematical solution to the 1-D transport equation (e.g. Ogata and Banks 1961; Bear 1972 & 1979). The often cited Ogata and Banks 1961 solution is a simple representation of advective-dispersive transport that does not incorporate the processes of adsorption (retardation) nor degradation. The Bear 1972 & 1979 solutions are more useful because they incorporate the effects of dispersion, retardation, and degradation.


1-D Example Application 

To illustrate the plume length that a 1-D model would calculate, a simple example was developed in which the Bear 1-D transport solution was used to calculate the location of the 5 ug/L plume boundary of a benzene plume 5880 days (16 years) after release (Fig 1). Source benzene concentration was assumed to remain constant at 1000 ug/L; groundwater velocity was set to 1 ft/d and retardation factor was set to 2; 1-D aquifer dispersivity was 50 ft; and a conservative benzene plume half-life of 2 years was applied. 

Fig 1. 1-D calculation shows plume extends 2900 ft from the source after 5880 days.

3-D Plume Transport Modeling

Another approach often employed by investigators or regulators is to begin with the full 3-D transport equation and apply that 3-D solution to calculate concentration along the centerline of the plume to determine the extent of the plume in the downgradient direction.

One of the widely known solutions to the 3-D transport equations was developed by Domenico in 1987. This solution forms the basis for a number of models used by regulatory agencies to estimate contaminant plume movement:

     BIOSCREEN developed by USEPA (see USEPA website for BIOSCREEN v1.4)

     BIOCHLOR (USEPA) v 2.2

     Quick Domenico model described by PADEP in certain of its regulatory documents (see PADEP website Quick Domenico spreadsheet model)


3-D Example Application 

So, we can now solve the same plume transport problem illustrated in Fig 1, but we will instead use the 3-D Domenico solution model (instead of 1-D). Transverse dispersivity is set to 1/10th the longitudinal dispersivity and vertical dispersivity is set to 1/1000th the longitudinal dispersivity (these parameters were not present in the 1-D model). The 3-D transport solution calculates a much shorter plume length; 1280 ft versus the 1-D length of 2900 ft (Fig 2).

Fig 2. 3-D calculation shows plume extends 1280 ft from the source after 5880 days.

Newer 3-D Methods

Analytical

In recent years minor discrepancies have been reported between the Domenico solution and more rigorous solutions to the 3-D transport equations (see for example (Guyonnet and Neville 2004; West et al 2007; Srinivasan et al 2007; Karanovic et al 2007; Devlin et al 2012). The discrepancies occur primarily along the centerline axis of the plume; this means that errors may be introduced when attempting to estimate the plume length (i.e. how far downgradient from the source contamination may extend).

Several investigators have modified the original Domenico 3-D transport solution to attempt to mitigate the errors caused by the original formulation. For example:

     BIOSCREEN (USEPA) was updated to BIOSCREEN-AT (Karanovic & Neville 2007)

     Srinivasan, Clement & Lee (2007) published an updated version of the Domenico solution


Semi-Analytical

The 1-D and 3-D solutions we have examined to this point are analytic solutions. Certain simplifications are made in the formulation of the transport differential equation that allows it to be solved in closed form - - i.e. the solution does not contain an integral term; the algebraic equation can be solved in a spreadsheet

There is a class of more rigorous solutions that are not simplified and still contain an integral term; and because of that, they are more accurate. These solutions are typically solved in a simple program that employs a numerical integration routine to arrive at the calculated concentrations.

Examples of these semi-analytical transport models include:

       ATRANS

       BIOSCREEN-AT (Domenico 1987 solution modified by Karanovic et al 2007)

       3DADE (USDA 1994)

       N3DADE (USDA 1997)

       AT123D-AT (Yeh 1984 solution modified by Burnell et al 2012)

These solutions have been assembled into a unified user interface in TS-CHEM. They provide a means of calculating more accurate estimates of contaminant plume extent for environmental assessments.


To summarize: Contaminant plume analyses based on 1-D models are likely to greatly overestimate plume extent. This may result in an overly-conservative assessment that causes concern, or results in actions, related to impacts that are not likely to occur. More accurate evaluations of plume extent can be calculated using 3-D contaminant transport model. TS-CHEM provides a library of over 30 analytical 3D plume transport solutions for making these types of evaluations.


To learn more about TS-CHEM, or to download a FREE DEMO VERSION of the software, visit the TS-CHEM Website today!



 

No comments:

Post a Comment